summaryrefslogtreecommitdiff
path: root/main.tex
diff options
context:
space:
mode:
Diffstat (limited to 'main.tex')
-rw-r--r--main.tex7
1 files changed, 3 insertions, 4 deletions
diff --git a/main.tex b/main.tex
index ab51130..27b1069 100644
--- a/main.tex
+++ b/main.tex
@@ -59,7 +59,7 @@
The literature on DCDTs is scarce.
Some systems barely classify as DTs (\emph{e.g.,} Kalibre~\cite{DBLP:conf/sensys/WangZD0TCWZ20}, ChatTwin~\cite{DBLP:conf/sensys/LiW0Z0T23}).
Existing deployments specialize in \textcolor{Red}{Cooling and Heat Modelling}, together with \textcolor{Red}{3D visualizations}.
- Most lack crucial predictive DC behaviour modelling.
+ Most lack predictive modelling of DC operations.
\end{tcolorbox}
\input{images/table.tex}
% Research on DTs for datacenters have been separate, siloed efforts focused on either datacenter cooling, network performance, power consumption or visualization efforts.
@@ -71,8 +71,7 @@
% Mandatory: split the figure into 2: top and bottom, and that way you can fill in the entire slide nicely.
\begin{tcolorbox}[title=A holistic DCDT system model]
- We propose a generic model of datacenter digital twinning that can be mapped to each system from \textbf{Table 1.1}. To answer \textbf{RQ2}, we design a ref. arch. for \emph{Operations Model}.
- We introduce the \emph{Digital Thread}: a bridge between software and reality.
+ We propose a generic model of datacenter digital twinning that can be mapped to each system from \textbf{Table 1.1}. Within this model (see \textbf{Fig. 1.3}) we introduce a concept of the \emph{Digital Thread}: a bridge between the DC digital twin and the physical DC equipment.
\end{tcolorbox}
\begin{center}
\vspace{-0.1cm}
@@ -84,7 +83,7 @@
% Not really a digital twin per se.
\tiny
- \textbf{Figure 1.3:} To answer \textbf{RQ1} we designed a generic datacenter digital twin system model based on a comprehensive literature review and findings from \textbf{Table 1.1}. The \emph{Infrastructure Model} simulates the structure of the DC and the \emph{Operations model} simulates the behaviour of the DC.
+ \textbf{Figure 1.3:} To answer \textbf{RQ1} we designed a generic datacenter digital twin system model based on a comprehensive literature review and findings from \textbf{Table 1.1}. The \emph{Infrastructure Model} simulates the structure of the DC and the \emph{Operations Model} simulates the behaviour of the DC.
% Consider splitting the figure into 2 a.k.a. top and bottom.
% By the AIAA definition, the DT mimicks the structure and behaviour.
% Data Lake -> Data Storage